Hi all,

I am running adapter on cnc machine .but intermittently facing issue that part count value is changing from some value (like 2000 to 599999) to very high value . and its than increasing from same high value .some time from again for 20-50 min showing same lower value like (599999 to 2000)however all other value is same .i am unable to understand why this is happening .

Below is CMD log.

dding pmc 'SspeedOvr' at location 30
Adding pmc 'Fovr' at location 12
2022-08-25T17:31:31.088Z - Info: Server started, waiting on port 7878
2022-08-25T17:31:31.202Z - Info: Connected to: 127.0.0.1 on port 60928
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-25T17:31:31.558Z - Info: Configuring...

2022-08-25T17:31:31.560Z - Info: Configuration for path 1:
2022-08-25T17:31:31.562Z - Info: Max Axis: 32
2022-08-25T17:31:31.563Z - Info: CNC Type: 0
2022-08-25T17:31:31.564Z - Info: MT Type: M
2022-08-25T17:31:31.566Z - Info: Series: D5
2022-08-25T17:31:31.568Z - Info: Version: 11
2022-08-25T17:31:31.569Z - Info: Axes: 04
2022-08-25T17:31:31.599Z - Info: Axis 0 : X
2022-08-25T17:31:31.601Z - Info: Axis X #0 - actual (unit 0 flag 0x15)
2022-08-25T17:31:31.604Z - Info: Units: mm
2022-08-25T17:31:31.608Z - Info: Axis 1 : Y
2022-08-25T17:31:31.612Z - Info: Axis Y #1 - actual (unit 0 flag 0x15)
2022-08-25T17:31:31.626Z - Info: Units: mm
2022-08-25T17:31:31.632Z - Info: Axis 2 : Z
2022-08-25T17:31:31.638Z - Info: Axis Z #2 - actual (unit 0 flag 0x15)
2022-08-25T17:31:31.643Z - Info: Units: mm
2022-08-25T17:31:31.646Z - Info: Axis 3 : A
2022-08-25T17:31:31.649Z - Info: Axis A #3 - actual (unit 0 flag 0x5)
2022-08-25T17:31:31.657Z - Info: Units: mm
2022-08-25T17:31:31.685Z - Info: Spindle 0 : S1
2022-08-25T17:31:31.688Z - Info: Current path: 1, maximum paths: 1
2022-08-25T17:31:31.973Z - Warning: Cannot cnc_rdntool for path 1: 0
2022-08-25T17:31:31.976Z - Warning: Trying modal tool number
2022-08-25T22:30:03.058Z - Error: Cannot cnc_rdexecprog for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-25T22:52:58.690Z - Error: cnc_rdsvmeter failed for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-25T23:43:48.449Z - Error: Cannot cnc_rdexecprog for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-25T23:45:46.069Z - Error: Cannot cnc_rdexecprog for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-26T00:28:49.353Z - Error: Cannot cnc_rdexecprog for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-26T01:15:08.606Z - Error: Cannot cnc_rdexecprog for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-26T01:23:46.861Z - Error: Cannot cnc_rdexecprog for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0
2022-08-26T01:25:37.592Z - Warning: cnc_modal failed for T on path 1: -16
Could not retrieve PMC data at 30 for SspeedOvr: -16
Could not retrieve PMC data at 12 for Fovr: -16
2022-08-26T01:25:37.701Z - Error: Cannot cnc_rdexecprog for path 1: -16
Machine has disconnected. Releasing Resources
Connecting to Machine at 192.168.1.8 and port 8193
Result: 0

![image](https://image