Settings ReadIntervalTimeout and ReadTotalTimeoutMultiplier to MAXDWORD in the COMMTIMEOUTS structure on Windows makes Windows behave as normally expected; a read call to the serial port will return immediately if there is any data available, or if a single byte arrives in the buffer. If no data arrives, it will timeout out after the timeout specified in ReadTotalTimeoutConstant. This fixes issues where reading from a serial port would take longer than desired when less data arrives that there is room for in the buffer passed to the read function. See also: https://learn.microsoft.com/en-us/windows/win32/api/winbase/ns-winbase-commtimeouts
|
Ping me when this is accepted in serialport and I'll give it a detailed look |
|
@estokes this has now been released with serialport-rs 4.4 :) |
|
@larsch I may have encountered an issue with this as I have been testing it. It seems that you get the EOF condition somewhat unexpectedly with the serial port, causing I might work up a fix for this if I can. |
|
Just based on my rudimentary understanding, which is not yet complete, I think that we need to detect somewhere ( This might also not block this PR since this is a change forced upon |
- Removes bad timeout overrides - See: - berkowski#38 - berkowski#47 - serialport/serialport-rs#79 - serialport/serialport-rs#73 (comment) - Cleans up unused imports
|
Given that the fix is accepted in serialport, would you like to amend this PR to completely remove the override? |
This is the equivalent of the PR serialport/serialport-rs#79. I would actually recommend completely removing the COMMTIMEOUTS override in mio-serial when/if the patch is accepted on serialport-rs, as this will solve the issue of read not returning available data until buffer is full or timeout. However, without this patch, the fix in serialport-rs does nothing.
This behavior is critical for and request/response protocol. I see 27-30 millisecond minimum latency on reads for data that takes <1ms to transfer, which is unacceptable.
Original change description:
Settings ReadIntervalTimeout and ReadTotalTimeoutMultiplier to MAXDWORD in the COMMTIMEOUTS structure on Windows makes Windows behave as normally expected; a read call to the serial port will return immediately if there is any data available, or if a single byte arrives in the buffer. If no data arrives, it will timeout out after the timeout specified in ReadTotalTimeoutConstant.
This fixes issues where reading from a serial port would take longer than desired when less data arrives that there is room for in the buffer passed to the read function.
See also: https://learn.microsoft.com/en-us/windows/win32/api/winbase/ns-winbase-commtimeouts