We read every piece of feedback, and take your input very seriously.
To see all available qualifiers, see our documentation.
Formula used to calculate Rt based on ADC measurement:
Rt = R x ADC / ( 1024 - ADC ) where R = 120k
Rt is then looked up in a table with values ranging from 0 to 50 degrees. Interpolation is used to get to an accuracy of 1 decimal.